Steel Structure  Lightweight AAC Wall Panel

Material: Comcrete
Refractoriness: 800-1400°C
Diameter: 00
Apparent Density: 520-620 Kg/M3
Surface Treatment: 00
Color: White
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other

Basic Info.

Model NO.
AAC Panel
Raw Materials
Silicon, Sand, Cement, Lime, Gypsumets, Steel
Application
Shopping Malls, Hospitals, Schools, Apartments,
Transport Package
with Standard Wooden Pallets and Containers or Bul
Specification
50mm, 75mm, 100mm, 120mm, 150mm, 200mm, 250mm, 300
Trademark
Eastland
Origin
China
Production Capacity
1000000 Cubic Meter/Cubic Meters Per Year

Product Description

Steel Structure Lightweight AAC Wall Panel

 

AAC WALL CLADDING PANEL (EASTLAND PANEL) is a steel reinforced Autoclaved Aerated Concrete Panel. It's characterized by steel-reinforced, load-bearing, lightness, sound and heating insulation, fireproofing, environmental protection, etc. EASTLAND PANEL is also widely used to erect civil constructions (shopping malls, hospitals, schools, apartments, villas, etc) and industry constructions for floors, walls (exterior and interior), roofs, partitions, fences, etc. EASTLAND PANEL has been recognized internationally and has gained the certifications of ASTM for USA, EN for New Zealand and AS for Australia.EASTLAND PANEL can replace traditional precast concrete and clay bricks. The Panel can be easily cut, drilled and screwed when installed. 

 

Here are the standard sizes and special sizes:

     
roduct No. Size of Product    
    Length (mm) Height/Width (mm) Thickness (mm)
External Panel KQB ≤3600 600 100
    ≤4200   120
    ≤5200   150
    ≤6000   200
    ≤6000   250
    ≤6000   300
Internal Panel KGB ≤3000 600 75
    ≤4000   100
    ≤5000   120
    ≤6000   150
    ≤6000   200
    ≤6000   250
    ≤6000   300
       


Advantages

 

Lightness

Specific gravity 0.5 Floating on the water.The dry specific gravity of the AAC panel is only 0. 5 because it is oneof foamed concrete. As the above rate is 1/5 of common concrete
1/3 of hollow block, it lightens the self-weight of building, reduces
the cost of base and frame, cuts down the difficulty in process of
soft groundsill, and increases the construction quality.

 

Sound Insulation

A lot of micro and small air holes that are inside the AAc panel cause
multi-function of sound insulation and assimilation. The high precision ofpanel can create a fine air keeping space to supply a silent and
comfortable living environment.

 

Heat Insulation

Rate of heat transmission 0.11 1/10 of common concrete.A lot of micro and small air holes that are inside of the AAC panel form a static air layer in the material and make the rate of heat transmission of only 0.11W/m K. The function of heat insulation and preservation of the AAC panel is 10 time of common concrete. The function of heat preservation of AAC panel at 125mm thickness is same as 370mm wall of soil-block.

 

Anti-Vibration

It is world-wide outstan." known of the anti-vibration ability of AAC panel
Only the constructions built with AAC panel are broken lightly at heavy
earthquakes at Osaka/Kobe
The tests in the laboratories of Tongji University and Southeast University in China show that the AAC panel has excellent function of anti-vibration
he light self-weight of AAC is the main cause, as it allows bigger angular distortion between layers and the allowed changing angle is 1/150.

 

Fireproofing

Panel for wall----Fireproofing in 4 hours
The AAC panel can stand against fire as the low rate of heat
transmission. The self of AAC belongs to abio-compound and is not
burnable. It doesn't produce nocuousness gas. At Tianjin National
Fixed Anti-fire System Center, it passed the test for fire bearing of
240 min limit.

 

Loading ability

The AAC panel can bear wind load, snow load and dynamic load
There are following types of the AAC panels:
Outside wall panel
Inner wall panel
Roof panel
Floor panel
The steel ribs inside of AAC panel are arranged by CAd according to loading situation, that the capacity of loading is obtained.
In general, the loads of building are
1.Constant load (incl. self weight and floors)
2. Living load
3. Snow load
4. Wind load
5. The effect of earthquake